AC Maintenance Checklist
A printable air conditioner tune-up checklist for the spring cooling visit, with blanks for static pressure, temperature drop, capacitor and amp readings.
How to use| Item | OK | Needs attention | N/A | Notes |
|---|---|---|---|---|
| Indoor: evaporator coil and air handler | ||||
| Cabinet secure, clearances kept clear | ||||
| Air filter checked / replaced (size: ) | ||||
| Evaporator coil and fins inspected / cleaned | ||||
| Condensate drain and pan clear | ||||
| Secondary pan / float switch tested | ||||
| No biological growth in pan or coil area | ||||
| Blower cleaned and adjusted | ||||
| Static pressure ( in. w.c.) vs manufacturer | ||||
| Temperature drop across coil ( °F) | ||||
| Pressure drop across coil recorded | ||||
| Outdoor: condensing unit | ||||
| Cabinet secure, clearances clear of debris | ||||
| Disconnect, grounding and voltage ( V) | ||||
| Contactor, circuit board and wiring checked | ||||
| Capacitor tested (rated / actual µF) | ||||
| Compressor and fan amps ( A / A) | ||||
| Condenser coil and fins cleaned | ||||
| Condenser fan motor checked | ||||
| Line set insulation intact | ||||
| Refrigerant and controls | ||||
| Leak check: no oil traces at joints or coils | ||||
| Charge checked per manufacturer if airflow OK but temp drop off | ||||
| Moving parts lubricated where required | ||||
| Electrical connections tightened | ||||
| Thermostat and controls: start, run and shut-off cycle OK | ||||
How to use
- The AC template is already loaded, with indoor coil, outdoor condensing unit, and refrigerant and controls sections.
- Add your business name, logo and the job details, or leave them blank to fill in by hand.
- Edit, add, remove or move items and sections. The preview updates as you type.
- Press Print, or Save as PDF and choose “Save as PDF” in the print window.
- Save a draft to reuse the same checklist on your next job.
About this AC maintenance checklist
Use it for a central AC tune-up or a cooling service agreement visit. The items follow the evaporator coil and condensing unit tasks in the ACCA 4 residential maintenance standard, plus the ENERGY STAR cooling check-up list. ENERGY STAR recommends a professional cooling check-up every spring, and notes that airflow problems can cut efficiency by up to 15%.
The U.S. Department of Energy suggests checking the evaporator coil every year and cleaning it as needed. Check the refrigerant charge against the manufacturer's method when airflow is right but the temperature drop is off. For heating, use the furnace maintenance checklist or the combined HVAC maintenance checklist.
Want the spring and fall visits side by side, with the readings to write down? Read our HVAC tune-up checklist guide.
Follow your local code and manufacturer instructions; this is a general checklist.
Questions
How often should an AC be serviced?
ENERGY STAR recommends a professional cooling check-up every spring, with the air filter checked monthly. Follow the equipment manufacturer.
Should refrigerant be checked every visit?
Look for signs of a leak, such as oil at joints, each visit. Check the charge using the manufacturer's method, especially when airflow is right but the temperature drop across the coil is off.
Can I add my own items?
Yes. Edit any item on the sheet, or open the custom builder to add sections, then print or save a PDF.