HVAC tune-up checklist: what a full visit covers

A tune-up is a pre-season check-up. The cooling side gets done in spring and the heating side in fall. On both visits the tech checks the thermostat and controls, tightens electrical connections, measures voltage and current on the motors, lubricates moving parts and clears the condensate drain. Then come the seasonal items: coils, refrigerant level and blower on the cooling visit, and gas connections, gas pressure, burner combustion and the heat exchanger on the heating visit.

That list is ENERGY STAR's, from its maintenance checklist for homeowners. It's a fair minimum. What separates a real tune-up from a quick look is whether the numbers get written down, so this post goes through each visit line by line with the readings worth recording.

A starting point, not a manufacturer requirement. The equipment manufacturer's instructions, your local code and any service agreement with the customer come first.

Run it in the right weather

ANSI/ACCA 4 QM, the ACCA standard for maintaining residential HVAC systems, says cooling and heating inspection tasks should be done while the equipment is running inside the manufacturer's temperature range. A cooling tune-up on a cold day can't give you honest readings. If the weather won't cooperate, note it on the sheet and come back for the readings.

The spring visit: cooling

Our AC maintenance checklist splits this visit into three parts.

Indoor: coil and air handler

  • Filter checked or replaced. Write the size down.
  • Evaporator coil inspected and cleaned if needed.
  • Condensate drain and pan clear, and the float switch tested if there is one.
  • Blower cleaned and adjusted.
  • Static pressure compared with the manufacturer's figure.
  • Temperature drop across the coil recorded.

The blower and airflow lines matter more than they look. ENERGY STAR says airflow problems can cut a system's efficiency by up to 15 percent.

Outdoor: condensing unit

  • Clearances clear of leaves and debris.
  • Voltage at the disconnect recorded.
  • Contactor and wiring checked.
  • Capacitor tested, with the rated and actual readings written side by side.
  • Compressor and condenser fan amps recorded.
  • Condenser coil cleaned.
  • Line set insulation intact.

Refrigerant and controls

Look for oil traces at joints and coils. Check the charge the way the manufacturer says to, and only after you know the airflow is right. If the filter or coil is dirty, fix the airflow before you touch the charge. Finish by running the thermostat through a full start, run and shut-off cycle.

The fall visit: heating

The furnace maintenance checklist is longer, because a gas appliance has more ways to go wrong.

Cabinet, electrical and air

Clearances around the furnace, line voltage, wiring and relays, motor amps against the nameplate, and the thermostat calling for heat. Then the filter and blower wheel. On a condensing furnace, add the condensate drain and trap.

Burners and ignition

  • Inlet and manifold gas pressure, both written down.
  • Igniter and flame sensor checked and cleaned.
  • The ignition and flame safety sequence tested.
  • Heat exchanger looked over for cracks, with the flame watched while the blower starts.
  • Flame steady and blue. Yellow or orange is a reason to dig further.
  • Combustion analysis done and the readings recorded.
  • Temperature rise measured and checked against the range on the nameplate.

Combustion air and venting

Enough combustion air, a vent that's supported and sloped correctly with a clear termination, and nothing stored against the flue. ACCA 4 lists most of the combustion and venting tasks as annual, so the fall visit is where they belong.

What to leave with the customer

ACCA 4 expects the contractor to record measurements and observations and to note recommended fixes. Its list of minimum paperwork includes the checklist itself, with any skipped task explained, plus code violations, parts you couldn't reach and the repairs the homeowner approved. It also says the homeowner has to be told about fixes that aren't part of the inspection, with approval agreed before that work is done.

In practice that means a filled-in sheet, not a sticker on the furnace. Mark each line, write the readings in the Notes column, and price anything extra as a separate line the customer can say yes or no to. Keep a copy. Next season, a capacitor reading that dropped or a temperature rise creeping toward the top of its range is what tells you a repair is coming.

Plan features change, so check Jobber's own pricing page before you pick a tier.

Comparing tune-up offers

If you're a homeowner looking at two tune-up prices, ask each company for its checklist and hold it up against the lists above. A visit that skips the electrical readings or the coil cleaning is a lighter visit, whatever it's called. On gas heat, ask whether a combustion analysis is included. Then ask whether you get the filled-in sheet afterward. A company that writes the readings down has something to compare against next year.

Which sheet to print

Use the AC checklist for the spring visit and the furnace checklist for the fall one. For a heat pump, or a one-trip visit that covers both, the HVAC maintenance checklist puts both seasons on a single page. For heat pump owner jobs and winter defrost checks, see our heat pump maintenance checklist. If you're working out when each customer is due, our guide to building an HVAC maintenance schedule covers the calendar side.

How long does an HVAC tune-up take?

It depends on the equipment and what you find, so there's no fixed time. A visit that includes coil cleaning and a combustion analysis takes longer than a quick visual check.

Is a tune-up the same as a maintenance plan?

No. A tune-up is one visit. A maintenance plan is an agreement to do those visits on a schedule, for example a cooling visit every spring and a heating visit every fall.

Can the homeowner do any of this?

The filter. ENERGY STAR tells homeowners to check it once a month and clean or change it as needed. The electrical, refrigerant and gas checks are for a qualified technician.