Heat pump maintenance checklist: owner jobs and the service visit

Heat pump maintenance comes in two parts. The owner keeps the filters clean, keeps the outdoor unit clear of debris and snow, and makes sure the condensate line drains. A technician services the system on the interval in the manufacturer's instructions or warranty, which New York's state energy agency says is every 1 to 2 years for most units. That visit covers the refrigerant charge, leaks, airflow, both coils and the drain pan, plus the electrical terminals and the backup heat.

The rest of this post breaks those two lists down line by line. It also covers what changes in winter, since the outdoor unit keeps running when it's cold and frosty, and a cold-weather problem won't show up on a summer visit.

A starting point, not a manufacturer requirement. The installation manual and the warranty terms come first, along with any service agreement. Where they give a different interval, use theirs.

Owner jobs between visits

Heat pump owner checklist
TaskHow often
Check the filter. Wash or replace it when it's dirty.Look monthly. Ducted filters are often replaced about every 90 days, depending on the filter.
Ductless indoor units: vacuum or rinse the filtersAt least monthly, more often with pets
Outdoor unit clear of debris, with plants trimmed back from the cabinetAll year
Snow and ice cleared away from the outdoor unitAfter significant snowfall
Look over indoor and outdoor units for damage, mold, ice buildup or dripping waterAt least once a season
Condensate line clear and draining somewhere safeDuring the cooling season
Supply registers and return grilles cleanedOnce a year

The filter intervals don't all agree, and that's fine. ENERGY STAR tells owners to check the filter once a month and clean or change it as needed. A heat pump fact sheet from NYSERDA says ducted filters usually get washed or replaced about every 90 days, depending on the filter's type, size and thickness, and that the filters in ductless heads should be cleaned at least monthly. The way to square it is to look every month and change it when it needs it.

One more owner habit from the same NYSERDA sheet: if the unit's filter indicator light comes on, clean the filter before you call for service.

Printing it as a checklist

Our HVAC maintenance checklist already includes a line for the reversing valve and defrost. For an all-electric heat pump, delete the gas furnace lines and keep the rest. For a ductless mini split, the ductwork and static pressure lines can go too. Then add the heat pump items from the technician list below that aren't on the sheet yet. A good one to add is "backup heat only comes on when needed." Save it as a draft and it's ready for the next visit.

The technician visit

NYSERDA's air source heat pump maintenance sheet lists what the service technician should be able to do. Here it is as checklist lines, with what's worth writing down beside each one:

  • Refrigerant charge checked. Record the readings, and check the airflow first.
  • Refrigerant leaks checked.
  • Oil leaks at the compressor checked.
  • Airflow verified. Write down the static pressure or temperature split you used.
  • Outdoor coil and indoor coil cleaned.
  • Condensate drain pan cleaned and the drain checked for clogs.
  • Electrical terminals inspected.
  • Duct leaks sealed where they can be reached.
  • Refrigerant line insulation intact and UV protected.
  • Thermostat settings confirmed.
  • Supplemental heat checked so it only comes on when it's needed.

ENERGY STAR's general check-up list adds a few lines that suit any system. Tighten the electrical connections and measure voltage and current on the motors. Lubricate moving parts that need it. Then run it through a full cycle from start to shut-off. It also notes that airflow problems can cut a system's efficiency by up to 15 percent, which is why airflow comes before the charge.

Plan features change, so check Jobber's own pricing page before you pick a tier.

One visit a year or two?

A furnace sits idle all summer and an air conditioner sits idle all winter. A heat pump does both jobs. ENERGY STAR suggests pre-season check-ups, with the cooling system in spring and the heating system in fall, because contractors get busy once the hot and cold weather arrives. On a heat pump you can do it as one full visit, or split it so the cooling checks happen in spring and the heating and defrost checks happen in fall. Either way, the manufacturer's interval is the minimum. If you want help setting up the dates across a list of customers, our post on building an HVAC maintenance schedule covers the calendar side.

Winter checks

A heat pump owner's guide on the Department of Energy's Building Science Education site covers the cold-weather questions people ask most.

  • Frost on the outdoor coil is normal. Below freezing, the unit runs a defrost cycle now and then. It switches to cooling mode to melt the ice, the fans may stop or slow, and backup heat may come on. Defrost typically takes 5 to 15 minutes.
  • Ice that won't clear isn't normal. A unit stuck in defrost or covered in ice needs a technician.
  • Watch where the melt water goes. It drips at the outdoor unit. Make sure it doesn't pool and refreeze on a walkway.
  • Don't cover the unit for winter. It needs airflow to pull heat from the outside air. Keep roof runoff and snow off it instead, which is usually a placement question for the installer.
  • If the thermostat keeps showing auxiliary heat, ask a technician to check the system. Strip heat costs a lot more to run.

Signs it needs a service call now

The same guide says the most obvious sign of trouble is a sudden jump in electricity use on the bill. Other signs on its list:

  • The heat pump won't run, or it keeps cycling off and on.
  • The room never reaches the set temperature.
  • High humidity indoors.
  • Loud noise from the unit or the ductwork.
  • Strange smells.
  • Frozen indoor or outdoor coils.
  • Mold growing near the unit.

Write any of these on the sheet's notes line with the date, even if you're about to fix it. A pattern over two or three seasons is often what points at the real cause.

Other sheets that help

If you'd rather split the visit by season, the AC maintenance checklist covers the cooling side in more detail, with lines for the capacitor, motor amps, coil temperature drop and static pressure. Our HVAC tune-up checklist post goes through the readings worth recording on a cooling visit.

How often should a heat pump be serviced?

Follow the manufacturer's instructions or warranty. NYSERDA says most call for service every 1 to 2 years. Owner jobs like checking the filter happen far more often, about monthly.

Should I cover my heat pump in the winter?

No. The outdoor unit needs airflow to work in heating mode. Protect it from roof runoff and heavy snow instead, and clear snow away from it after heavy snow.

Is it normal for a heat pump to have frost on it?

Yes, light frost below freezing is normal and the defrost cycle clears it, typically in 5 to 15 minutes. If the unit stays iced over or stuck in defrost, call a technician.